VFD Frequency Converter Repair

VFD / Frequency Converter Repair

Frequency converter repair, from fault code to full load

DC bus faults, blown output stages, dead control boards — we repair AC drives and frequency converters at component level, then run each unit up to rated output before it goes back in your cabinet.

Every unit gets a reference, a report and a warranty
// output clean, motor running smooth
How it works

A process built around trust

01 · Reception

Reception & inspection

Your converter arrives, gets logged under its own case reference, and goes through a full visual and electrical check before it's powered up.

02 · Diagnosis

Diagnosis & quotation

We trace the fault to the rectifier, DC bus, IGBT stage or control board, and send a clear quote. Nothing gets repaired until you approve.

03 · Return

Repair, test & return

Once approved, we repair the unit and run it up to rated load before shipping it back with a full report.

What we see

Common frequency converter faults

  • DC bus capacitor failure and undervoltage or overvoltage trips
  • Shorted IGBT output modules after a motor or ground fault
  • Failed input rectifier bridge or soft-charge circuit
  • Control board component failure with no display or keypad response
  • Cooling fan failure and overtemperature shutdowns
  • Damaged EMC filters and input choke faults
  • Profibus, Modbus or Ethernet communication card faults
  • Lost or corrupted parameter sets after a fault event

Repair happens at component level, so a discontinued model rarely rules a unit out — including converters the original manufacturer no longer supports.

Coverage

Brands and series we work on

  • ABB ACS series drives
  • Danfoss VLT and VACON drives
  • Siemens Sinamics G120 / V20 / Micromaster
  • Schneider Electric Altivar series
  • Yaskawa V1000 / A1000 / GA700
  • Mitsubishi FR series
  • Emerson / Control Techniques drives
  • Legacy and obsolete converter models
What you get

What every converter repair includes

Traceability

A unique case reference and a full repair report follow your converter from the moment it arrives.

Load-tested

Every repaired unit is run up to rated output, not just powered on, before it leaves the workshop.

Root-cause insight

When a drive keeps tripping, we dig into why — motor, cabling, or the drive itself — and flag it in the report.

Warranty

Repairs are backed by a standard warranty, so you're covered once the converter is back in service.

Decide faster

Repair or replace?

Choose repair when

  • The exact model is discontinued or hard to source quickly
  • Existing parameter sets and wiring should stay untouched
  • You need a traceable repair with a report and warranty
  • The application runs in a harsh environment where load testing matters

Consider replacement when

  • You need the line running now and a matched spare is ready
  • A motor or process upgrade is already planned
  • New firmware features or fieldbus support are actually needed
Before you ship

Get it to us the right way

  • Photograph the nameplate, keypad and any visible damage before you pack it up.
  • Note any fault code shown on the display when the unit last tripped.
  • Write the case reference on both the unit and the box.
  • Describe the input voltage, motor size, and when the fault happens.
  • Use anti-static protection for control boards and pack it so it can't shift in transit.
On-site option

When the fault only shows up in the cabinet

Some faults only appear under real load, wiring, or grounding conditions a bench test can't reproduce. When that's the case, we can send an engineer to you instead.

Get started

Ready to get your line running again?

Tell us what's failing and we'll take it from there.